
UNITED CHEMICAL · TOOTETEHNOLOOGIA · 27. NOVEMBER 2026
Purity is the starting point, not the answer
Two briquettes with the same assay can differ by double digits in consumed kilograms per tonne.
A gold plant buys Naatriumtsüaniid on an assay. It loses money on dissolution. The number that decides how many kilograms disappear per tonne of ore is how fast the briquette releases tsüaniid into solution and how steadily the circuit holds a free-cyanide setpoint. A high-purity product that dissolves unevenly creates dosing lag, over-addition and WAD-cyanide excursions. This note sets out the working controls for AuCyan™ naatriumtsüaniid NaCN (≥98.3%) and gives a plant-ready method for measuring them.
1. What the Elsner equation does and does not tell you
Gold dissolution follows the Elsner equation: 4 Au + 8 CN⁻ + O2 + 2 H2O → 4 [Au(CN)₂]⁻ + 4 OH⁻. Two moles of cyanide per mole of gold, roughly 0.5 g NaCN per gram of gold. A circuit treating 3,000 t/day at 2 g/t and recovering 95% consumes under 3 kg/day in the ideal reaction.
Real plants consume hundreds of kilograms a day. Everything above the stoichiometric minimum is base-metal demand, hydrolysis, degradation or physical loss — and three of those four are controllable. That is where a dissolution specification earns its keep.
2. The consumption ledger
| Kahjumiskopp | Mehhanism | Kontroll |
|---|---|---|
| Kulla lahustumine | Stoichiometric, ~0.5 g NaCN/g Au | Useful consumption |
| Mitteväärismetallid | Copper and zinc form cyano-complexes | Ore blending, higher setpoint |
| Hüdrolüüs | CN⁻ + H₂O ↔ HCN + OH⁻ | Lime, pH interlock |
| Incomplete release | Unreacted briquette core in tails | Lahustumisprofiil |
Kuldne kolmnurk – kolm toodet, üks tarnija
AuCyan™ naatriumtsüaniid NaCN (≥98.3%) · AuCarb™ kookospähkli koore aktiivsüsi (kõvadus ≥99%) · AuLeach™ kulla leostusaine (GDA) – mitteohtlik
3. The dissolution test you should be running
Put a known mass of briquette in a stirred vessel at circuit pH and temperature. Sample the solution at 1, 3, 5, 10 and 20 minutes and plot cumulative cyanide release. The curve should be reproducible lot to lot. A product that reaches 90% release in five minutes in one drum and fifteen in the next will make a liar of every dosing calculation. Specify three clauses, not one: minimum assay ≥98.3%, time to 90% release, and maximum insoluble residue. Ask for the batch COA, TDS ja MSDS to confirm all three.
4. Worked check: the cost of a one-tank lag
Take 3,000 t/day, target free cyanide 0.25 g/L, solution-to-solids 1.2:1, measured ore demand 0.30 kg/t. Circuit inventory is 3,000 × 1.2 × 0.25 = 900 kg; daily ore demand is 900 kg. If dissolution lags one tank residence time, operators typically add 8–12% protection. That is 72–108 kg/day, or 26–39 t/year of reagent that never dissolves gold.
In-circuit inventory: 900 kg
Viivituskaristus 10% juures: 90 kg/päev ≈ 33 t/aasta
5. WAD cyanide is the report card
Weak-acid-dissociable cyanide in tailings tells you whether the circuit is over-dosing. A rising WAD number with flat recovery means reagent is leaving untreated. The response is not to cut the setpoint blindly — it is to check dissolution, re-run the bottle roll on the current ore domain and verify pH. Only then adjust the dose. This sequence prevents the classic error of cutting reagent and losing recovery together.
6. Veaotsing
| Sümptom | Põhjus | tegevus |
|---|---|---|
| Vaba CN triivib madalal | Dissolution lag or demand spike | Verify dissolution, re-run bottle roll |
| WAD cyanide rising | Üledoseerimine seadeväärtuse kaitsmiseks | Tighten curve, check pH |
| Valge sade | Põhimetallide tsüanokompleksid | Ore blend, alkaline wash |
| Pumba kavitatsioon | Undissolved fragments | Extend make-up time |
5b. Make-up water and temperature
Two site variables change the dissolution curve more than any certificate: make-up water and temperature. Hard water raises lime demand and can aggravate scale on pipework and screen surfaces; chloride and sulphate accumulate through process-water recycle and affect both leaching and Süsinik loading. Temperature shifts reaction kinetics, so a briquette that dissolves acceptably in a warm summer circuit can lag when winter make-up water drops the circuit temperature by several degrees. Establish a baseline for pH, alkalinity, hardness, chloride and sulphate before the campaign, then sample weekly. A dissolution test run at the plant's actual temperature and with its actual water is worth more than a laboratory result obtained under ideal conditions. If the curve changes with the seasons, the dosing schedule must change with it, not by guesswork but by re-measuring the release profile.
7. KKK-d
Q1 — Why specify ≥98.3% and not a higher number?
Because dissolution and insolubles decide consumed kilograms more than the last fraction of assay.
Q2 — What ships with a batch?
A batch COA, TDS and MSDS covering assay and dissolution behaviour.
Q3 — Which terms apply?
FOB and CIF only, from 1×20' FCL ≈ 18 MT.
Q4 — Is it a controlled good?
Yes. UN1689, DG Class 6.1; import licence and End-Use Certificate before shipment.
Q5 — Can the carbon come from the same supplier?
Yes — AuCarb™ with documented hardness and attrition.
Q6 — What if cyanide use is constrained?
AuLeach™ Gold Leaching Agent (GDA) – Non-Hazardous is the alternative route, selected by bottle-roll comparison.
Ask for the dissolution data
Send ore grade, setpoint and throughput. We return a dissolution-matched dosage proposal with COA, TDS and MSDS.
Võta meiega ühendust · Kuldse kolmnurga ülevaade · Naatriumtsüaniidi viide · Kemikaalide KKK · Tööstusuudised
WhatsAppi +86 173 9270 5576 · info@unitedchemicalcn.com
- Juhuslik sisu
- Kuum sisu
- Kuum arvustuste sisu
- Naatriumetüülksantaat 90% SEX
- Ettevõtte toodete tutvustus
- Oksaalhape kaevandamiseks 99.6%
- 99.5% min ammooniumkloriid Tööstuslikuks kasutamiseks
- Kaltsiumperoksiid 60% Assay Kollakas tablett
- 1Soodushinnaga naatriumtsüaniid (CAS: 143-33-9) kaevandamiseks – kõrge kvaliteet ja konkurentsivõimeline hind
- 2Naatriumtsüaniid 98.3% CAS 143-33-9 NaCN kulla sidumisaine, mis on oluline kaevanduskeemiatööstuses
- 3Hiina uued eeskirjad naatriumtsüaniidi ekspordi kohta ja juhised rahvusvahelistele ostjatele
- 4Naatriumtsüaniid (CAS: 143-33-9) Lõppkasutaja sertifikaat (hiina- ja ingliskeelne versioon)
- 5Rahvusvaheline tsüaniid (naatriumtsüaniid) halduskoodeks – kullakaevanduse aktsepteerimise standardid
- 6Hiina tehas 98% väävelhape
- 7Veevaba oksaalhape 99.6% tööstuslik kvaliteet
- 1Naatriumtsüaniid 98.3% CAS 143-33-9 NaCN kulla sidumisaine, mis on oluline kaevanduskeemiatööstuses
- 2Kõrge puhtusaste · Stabiilne jõudlus · Suurem saagis — naatriumtsüaniid tänapäevaseks kulla leostamiseks
- 3United ChemicalUurimisrühm demonstreerib autoriteeti andmepõhiste teadmiste kaudu
- 4AuCyan™ kõrgjõudlusega naatriumtsüaniid | 98.3% puhtusaste ülemaailmseks kullakaevandamiseks
- 5Digitaalne elektrooniline detonaator (viivitusaeg 0 ~ 16000 ms)
- 6Kõrge tugevusega ülitäpne põrutustoru detonaator
- 7tööstus elektridetonaator






Online sõnumite konsultatsioon
Lisa kommentaar: