Commissioning a Common-Chemical Leach Route Without Rebuilding the Circuit
The reagent changes; the tanks, screens and Koalstof circuit do not. What still has to be rebuilt is the validation logic.
AuLeach™ Gold Leaching Agent (GDA) – Non-Hazardous is a common-chemical Gouden útlûkreagens that drops into existing CIP, CIL, CIC, Heap leaching and Vat leaching circuits without a process redesign. It ships as general cargo under FOB or CIF terms, so the Class 6.1 permit chain that gates Natriumcyanide deliveries does not apply. That advantage is logistical, not metallurgical: dosage and pH still have to be fixed ore by ore, and local common-chemical import rules still have to be confirmed by the buyer.
Key Takeaways
- Non-Hazardous is a classification, not a performance claim. It describes how the product ships and is declared, not what recovery a given ore will deliver.
- The circuit stays. Existing tanks, agitation, screens and carbon adsorption stages are retained; the reagent and its control band change.
- Dosage is ore-dependent. The indicative 0.5–1.0 ‰ range must be fixed by bottle roll or column testing on the plant's own feed.
- pH 10.5–12 is the operating window, with a working target around 11 ± 1. Outside that band, dissolution and reagent stability both suffer.
- General cargo removes a schedule risk, but the buyer still confirms the destination's common-chemical import rules against the shipped documentation.
- Adsorption still needs AuCarb™. A different leach chemistry does not remove the need for a properly specified carbon circuit.
Produkt: AuLeach™ Gold Leaching Agent (GDA) – Net-gefaarlik · Terms: FOB or CIF · MOQ 28 MT per 1×20' FCL · Documents: batch COA, TDS, MSDS.
| parameter | spesifikaasje | Wêrom it der ta docht |
|---|---|---|
| Klassifikaasje | Non-Hazardous (common chemical) | General-cargo booking and declaration |
| Appearance / density | White to grey-white powder · 1.20–1.35 g/cm³ | Dosing and make-up handling |
| Operaasje pH | 10.5–12 (target 11 ± 1) | Dissolution stability and reagent control |
| Indicative dosage | 0.5–1.0 ‰ (500–1000 g/t ore) | Starting band before ore-specific validation |
| Packaging / MOQ | Net 25 kg bag · 28 MT | FCL planning and freight comparability |
Applicability covers oxide, primary, semi-oxide, sulfide, high-arsenic and refractory ores, gold concentrates and syanide tailings. Exact dosage is ore-dependent and must be fixed by laboratory testing before a plant campaign.
1. What changes and what does not
A leaching circuit is a set of unit operations: make-up and dosing, alkaline conditioning, dissolution under agitation or percolation, solid-liquid separation, and recovery of dissolved gold onto carbon. Switching to a common-chemical reagent changes the make-up chemistry and the control band. It does not, by itself, require new tanks, new screens or a new adsorption train. That is why the route is attractive for plants that already run CIP, CIL, CIC, Heap leaching or Vat leaching and want to avoid a capital project.
What must change is the validation package. A cyanide circuit has decades of shared operating heuristics; a common-chemical route does not. The plant needs its own dissolution curve, its own pH response, its own dosage calibration and its own residual-reagent measurement routine. Treating the indicative band as a fixed recipe is the most common commissioning error.
2. Four commissioning difficulties
2.1 Ore-specific response
Oxide ore, primary sulphide ore, high-arsenic material and cyanide tailings do not consume reagent at the same rate. A dosage that works on an oxide stockpile can under-dose a sulphide blend. Each distinct feed needs its own test curve.
2.2 pH drift during the campaign
Acidic ore components, make-up water quality and reagent degradation all move pH. Outside the 10.5–12 window, dissolution slows and control becomes erratic. pH must be logged at defined intervals, not checked once at start-up.
2.3 Residual reagent and solution balance
Recirculated process water accumulates dissolved salts and residual reagent. Without a measurement routine, the apparent consumption drifts and operators compensate by over-dosing, which raises cost without raising recovery.
2.4 Local import classification
General-cargo status removes the Class 6.1 chain, but destination authorities still apply their own common-chemical rules. The buyer confirms those rules against the shipped TDS and MSDS before the order is released.
3. Tutorial: seven-step commissioning sequence
- Characterise each feed separately. Record head grade, mineralogy, clay and sulphide content, arsenic level and particle size for every ore type or tailings stream that will enter the circuit.
- Run bottle roll tests across the 0.5–1.0 ‰ band at pH 10.5–12, sampling dissolved gold at 2, 6, 12 and 24 hours. Produce a curve per feed, not a single pass/fail result.
- Map the pH response. Identify where dissolution peaks and how quickly pH drifts for each feed; set the control band and the correction agent from that data.
- Fix the dosage by feed. Convert the laboratory optimum into kg/t of ore using pulp density and throughput, then define a separate set-point for each blend.
- Validate the adsorption stage. Confirm that AuCarb™ Gold Recovery Coconut Shell Activated Carbon (≥99% Hardness) still delivers the required K/R performance in the new solution chemistry before scaling up.
- Run a controlled plant trial on one circuit or one heap cell, logging pH, dosage, dissolved gold, residual reagent and recovery against the batch COA.
- Freeze the operating window and review it whenever the feed blend, water quality or throughput changes. Keep the test curves with the batch documentation for traceability.
The sequence is deliberately conservative: the reagent removes a logistics constraint, but it does not remove the need for metallurgical evidence. Plants that compress steps 1–5 into a single trial usually spend more time diagnosing the plant than they saved on the schedule.
4. Tabel foar probleemoplossing
| Symptoom | Wierskynlike oarsaak | Earste kontrôle |
|---|---|---|
| Recovery below bottle roll result | Scale-up gap in agitation, residence time or pH control | Plant pH log, residence time, mixing energy |
| Consumption climbing at fixed feed | Resterend reagens yn resirkulearre wetter | Solution balance, make-up water quality |
| Dissolution stalls mid-campaign | pH drifting out of the 10.5–12 band | pH profile, buffering capacity, correction rate |
| Carbon loading lower than expected | Nije oplossingskemy dy't ynfloed hat op adsorpsjesnelheid | R value retest, stage-by-stage solution tenor |
| High-arsenic ore underperforms | Feed-specific dosage not calibrated | Dedicated bottle roll curve for that blend |
| Shipment held at destination | Local common-chemical rules not confirmed | TDS, MSDS and import classification against local rules |
5. Three products, three decisions
| Beslút | Product | Governing constraint |
|---|---|---|
| Established cyanide circuit | AuCyan™ Natriumcyanide NaCN (≥98.3%) | Permit chain, free-cyanide control |
| Permit-constrained or general-cargo route | AuLeach™ Gold Leaching Agent (GDA) – Net-gefaarlik | pH band, ore-specific dosage validation |
| Gold recovery from solution | AuCarb™ Gold Recovery Kokosnootskulp Aktivearre Koalstof (≥99% Hardheid) | Hardness, K/R values, attrition, mesh cut |
All three ship under FOB or CIF terms with batch COA, TDS and MSDS. Free laboratory test samples are available for AuCarb™ and AuLeach™ so validation can start before an FCL order.
AngloGold Ashanti's 5 November 2026 brownfield programme includes roughly US$70 million at Siguiri in Guinea for about 100,000 oz/y of additional output, where Block 3 starts at the end of the year with 1.22 g/t feed replacing low-grade stockpile material. A change of feed grade on an existing circuit is precisely the condition under which a reagent control band must be re-validated rather than carried over. Source: company expansion announcement, 5 November 2026.
6. Faak stelde fragen
Q1. What does Non-Hazardous mean for this product?
It is a common-chemical classification that allows general-cargo booking and declaration. It is a shipping and regulatory description, not a recovery guarantee.
Q2. Does the plant need new tanks or screens?
No. AuLeach™ Gold Leaching Agent (GDA) – Non-Hazardous is designed to drop into existing CIP, CIL, CIC, Heap leaching and Vat leaching circuits without a process redesign.
Q3. What pH should the circuit hold?
An operating window of 10.5–12, with a working target around 11 ± 1, verified by routine measurement rather than a single start-up check.
Q4. What is the indicative dosage?
0.5–1.0 ‰, equivalent to 500–1000 g per tonne of ore. The figure is a starting band; the actual set-point is fixed by bottle roll or column testing on the plant's own feed.
Q5. Which ore types can be evaluated?
Oxide, primary, semi-oxide, sulfide, high-arsenic and refractory ores, gold concentrates and cyanide tailings — each with its own test curve.
Q6. Why does a feed change require re-validation?
Different mineralogy changes reagent demand, pH drift and dissolution kinetics. A dosage calibrated on an oxide stockpile will not automatically fit a sulphide blend.
Q7. Is the carbon circuit still needed?
Yes. Dissolved gold is still recovered by adsorption, so AuCarb™ Gold Recovery Coconut Shell Activated Carbon (≥99% Hardness) remains part of the flowsheet.
Q8. Does general-cargo status remove all import formalities?
No. The Class 6.1 permit chain does not apply, but the buyer still confirms local common-chemical import rules against the shipped TDS and MSDS.
F9. Hokker Incoterms binne beskikber?
FOB- of CIF-betingsten binne fan tapassing.
Q10. What is the minimum order?
28 MT per 1×20' FCL, packed in net 25 kg bags.
Q11. Can a laboratory sample be provided before an FCL order?
Yes — AuLeach™ test samples are available for laboratory validation alongside AuCarb™ samples.
Q12. When should a plant keep its cyanide route instead?
Where permits are in place and the cyanidation circuit is already optimised, AuCyan™ Sodium Cyanide NaCN (≥98.3%) remains the established dissolution benchmark. The common-chemical route is an alternative when the permit chain is the binding constraint.
7. Technyske lêzing en ynterne keppelings
AuLeach™ GDA product page · Leaching reagents reference · Oersjoch fan 'e Gouden Trijehoek · Technysk oersjoch fan trije produkten · AuCyan™ · AuCarb™-hantlieding · AC50 · AC55 · AC60 · BC1100 · Gemyske FAQs · Industry News
Kontakt Mei Ús Opnimme · WhatsApp +86 173 9270 5576 · info@unitedchemicalcn.com
- Willekeurige ynhâld
- Hot ynhâld
- Hot resinsje ynhâld
- Oanpaste gemyske oplossingen foar mynbou en mineralferwurking en technyske stipe foar Myanmar
- De 20 wichtichste reagenzjes yn mineralferwurking
- China Shaanxi United Chemical's High Hardness Gold Special Activated Carbon
- Navigearje feroaring: De takomstige rjochting fan 'e gemyske yndustry
- Kaliumhydroxide (solide)
- Natriumhexametafosfaat
- Ferrichloride (fast)
- 1Discounted Sodium Cyanide (CAS: 143-33-9) foar mynbou - Hege kwaliteit en konkurrearjende prizen
- 2Natriumcyanide 98.3% CAS 143-33-9 NaCN goudkleurmiddel essensjeel foar gemyske yndustry yn 'e mynbou
- 3Sina's nije regeljouwing oer eksport fan natriumcyanide en begelieding foar ynternasjonale keapers
- 4Natriumcyanide (CAS: 143-33-9) Sertifikaat foar einbrûker (Sineeske en Ingelske ferzje)
- 5Ynternasjonale cyanide (natriumcyanide) Management Code - Gold Mine Acceptance Standards
- 6Sina fabryk Sulphuric Acid 98%
- 7Anhydrous Oxalic acid 99.6% Industrial Grade
- 1Natriumcyanide 98.3% CAS 143-33-9 NaCN goudkleurmiddel essensjeel foar gemyske yndustry yn 'e mynbou
- 2Hege suverens · Stabile prestaasjes · Hegere herstel — natriumcyanide foar moderne goudútlûking
- 3United ChemicalUndersyksteam fan it bedriuw lit autoriteit sjen troch gegevensgedreven ynsjoch
- 4AuCyan™ Heechprestaasje Natriumcyanide | 98.3% Suverens foar wrâldwide goudwinning
- 5Digitale elektroanyske detonator (fertragingstiid 0 ~ 16000ms)
- 6Hoge sterkte, hege presyzje Shock Tube Detonator
- 7yndustry Electric Detonator






Online berjochtkonsultaasje
Opmerking taheakje: