Ékspansi Cuiabá US$200–250 Juta: Variabilitas Bijih Hard-Rock sareng Kasus pikeun Spésifikasi Réagen anu Konsisten

A 75,000 oz increment on an existing 194,000 oz base — plus a six-step method for holding one reagent specification across variable hard-rock feed.

Gold recovery reagent product range displayed for hard rock gold processing operations

Warta Industri · 5 Nopémber 2026

Hard-Rock Ore Variability and the Case for Consistent Reagent Specifications

When the ore changes from block to block, the one thing that should not change is the reagent you are measuring it against.

Jawab Gancang

AngloGold Ashanti plans to invest US$200–250 million at the Cuiabá gold operation in Brazil, adding roughly 75,000 ounces of annual production to a 2025 base of 194,000 ounces. It is a brownfield expansion on an existing hard-rock circuit. For a plant whose ore varies from block to block, the procurement priority is not a new reagent but a stable one: one assay, one mesh cut, one K/R specification and one documentation standard per lot, so any change in plant performance can be attributed to the ore rather than to the delivery.

Takeaways Key

  • A brownfield increment, not a new plant. US$200–250 million adds about 75,000 oz/y on a 194,000 oz 2025 base.
  • Hard-rock feed varies. Grind size, sulphide exposure and gold liberation change dissolution kinetics between blocks.
  • Hold the reagent constant. A stable NaCN assay and a stable karbon specification make ore variability measurable instead of ambiguous.
  • COA per lot is the control instrument. Batch COA, TDS and MSDS let operators separate ore effects from delivery effects.
  • Carbon hardness ≥99% and attrition ≤1.5% keep loaded fines off the tailings stream when throughput rises.
  • One qualification, one freight plan. FOB or CIF only, with 15 / 18 / 28 MT minimum order quantities per 1×20' FCL.
Tabel fakta anu ditanggalkeun · diumumkeun 5 Nopémber 2026
barangAngka anu diungkabkeun
Planned investment at CuiabáUS$200–250 juta
Incremental production~75,000 oz/y
Basis 2025194,000 oz
locationBrazil, within the wider brownfield programme

Source: company expansion announcement, 5 November 2026. All figures above are disclosed project numbers; no consumption figures have been estimated by the publisher.

1. Why ore variability makes specification stability valuable

In a hard-rock circuit, the ore delivered to the leach is never identical from one block to the next. Grind size changes liberation; sulphide and arsenic content change side-reaction demand; clay changes pulp rheology and oxygen transfer. Every one of those moves the dissolution curve and the reagent demand per tonne.

If the ore and the reagent both vary, the operator cannot tell which caused a change in recovery or consumption. Holding the reagent specification constant removes one variable. A NaCN assay that stays at ≥98.3%, a carbon lot that stays at ≥99% hardness with ≤1.5% attrition, and a fixed 6×12 mesh cut turn the reagent into a measuring instrument for the ore.

That is the practical argument for a single qualified supplier on a brownfield expansion: comparability. One set of test conditions, one documentation standard and one freight plan make deviations diagnosable.

2. Four difficulties in a variable hard-rock feed

2.1 Grind and liberation drift

Finer grind exposes more gold but also more gangue surface. Coarser grind leaves gold locked. Both change the optimum dosing profile, so the plant needs a curve per grind target.

2.2 Sulphide and arsenic side reactions

Copper, iron and arsenic minerals consume reagent through cyanocomplex formation. A new block with higher sulphide content raises consumption without raising recovery, which looks like a reagent problem unless the ore is tested.

2.3 Carbon fines at higher throughput

More circulation and screening cycles generate more fines. Because those fines carry adsorbed gold, the loss appears as a recovery gap rather than a consumable expense. Hardness ≥99% and attrition ≤1.5% on AC50 are the control points.

2.4 Multi-supplier drift

Two suppliers with nominally equivalent products can differ in assay, particle size distribution or impurity profile. Small differences compound across a long campaign and make trend data useless.

3. Tutorial: six steps to hold batch consistency

  1. Qualify one specification per product. Fix the NaCN assay band, the carbon hardness / attrition / mesh / K·R parameters and the leaching-agent pH and dosage band in writing before the first order.
  2. Require batch COA, TDS and MSDS per lot. File them against the delivery number, not in a shared folder, so any plant deviation can be traced to one lot.
  3. Sample on arrival. Retain a representative sample of each lot and verify the key assay or particle size parameter against the COA before the lot enters the circuit.
  4. Define an acceptance band. State what happens when a measured value falls outside it — hold, re-test or adjust the dosing set-point — and who authorises the decision.
  5. Log plant performance per lot. Consumption kg/t, pH, free sianida or residual reagent, dissolved gold and recovery should all sit next to the lot number.
  6. Separate ore effects from delivery effects. When performance shifts, check the ore blend first (step 1 of the feed-change method), then the COA. Do not adjust the set-point until both are known.

This routine costs little and protects the most valuable thing a plant owns during an expansion: comparable data.

4. Tabel pangungkulan masalah

ciriKamungkinan ngabalukarkeunPariksa heula
Consumption up, recovery flatNew sulphide / arsenic blockOre mineralogy, bottle roll curve
Recovery down after finer grindGangue surface consuming reagentGrind size distribution, dosing profile
Carbon make-up risingFines from higher circulationAttrition ≤1.5%, screen aperture, tails assay
Trend data inconsistentTwo suppliers or two specs in useQualification record, COA per lot
Deviation cannot be tracedLot number not linked to plant logDelivery record, sampling and filing routine

5. Three products under one qualification

PanggungbarangFixed specification
DisolusiNatrium Sianida AuCyan™ NaCN (≥98.3%)Assay band, low NaOH / Na₂CO₃ / insolubles; 18 MT MOQ
AdsorptionKarbon Aktif Batok Kalapa Pamulihan Emas AuCarb™ (Karasa ≥99%)6×12 mesh, attrition ≤1.5%, K ≥26 kg/t / R ≥50% on AC50; 15 MT MOQ
Jalur alternatifAgen Pelindian Emas AuLeach™ (GDA) – Henteu BahayapH 10.5–12, ore-validated dosage; 28 MT MOQ

All three ship factory-direct under FOB or CIF terms with batch COA, TDS and MSDS; AuCarb™ is packed in 25 kg heavy-duty laminated PE bags. Free laboratory test samples are available for AuCarb™ and AuLeach™.

6. Patarosan Sering

Q1. What is planned at Cuiabá?
US$200–250 million of investment, adding roughly 75,000 ounces of annual production to a 2025 base of 194,000 ounces.

Q2. When was this announced?
5 Nopémber 2026, dina program ékspansi brownfield perusahaan.

Q3. Why does hard-rock ore complicate reagent control?
Grind size, sulphide exposure, arsenic and clay content all change dissolution kinetics and side-reaction demand between blocks.

Q4. Why hold the reagent specification constant?
So any change in recovery or consumption can be attributed to the ore rather than to a varying delivery.

Q5. What documents should accompany each lot?
Batch COA, TDS and MSDS, filed against a delivery number so deviations are traceable.

Q6. What should be sampled on arrival?
A representative sample of each lot, verified against the COA for the key assay or particle size parameter before use.

Q7. Which carbon parameters matter most here?
Hardness ≥99%, attrition ≤1.5%, platelet ≤5.0%, a 6×12 mesh cut and the K/R pair on AC50.

Q8. Kumaha cara ngabungkus AuCarb™?
In 25 kg heavy-duty laminated PE bags at 15 MT MOQ per 1×20' FCL.

Q9. Incoterms mana anu lumaku?
Sarat FOB atanapi CIF lumaku.

Q10. What is the operating window for AuLeach™?
pH 10.5–12 with a target around 11 ± 1, with dosage fixed by ore-specific testing.

Q11. Should the set-point be adjusted when performance shifts?
Only after the ore blend and the batch COA have both been checked, so the cause is known before the change is made.

Q12. Di mana spésifikasi produk dipedalkeun?
On the AuCyan™, AuCarb™ and AuLeach™ technical pages linked below.

7. Sumber sareng tautan internal

AuCyan™ · Pituduh AuCarb™ · AC50 · AC55 · AC60 · BC1100 · AuLeach™ GDA · Segitiga Emas · Tinjauan tilu produk · FAQ Kimia · Warta Industri · Hubungi Kami

Catetan sumber: angka proyék dicandak tina pengumuman ékspansi perusahaan tanggal 5 Nopémber 2026. Spésifikasi réagén nyaéta United Chemical data produk.

Set up a batch consistency routine for your plant

Taros Kami · WhatsApp +86 173 9270 5576 · info@unitedchemicalcn.com

Anjeun oge bisa resep

Konsultasi pesen online

Tambahkeun komentar:

+ 8617392705576Kode QR WhatsAppKodeu QR scan
Ninggalkeun pesen pikeun konsultasi
Hatur nuhun pikeun pesen anjeun, kami bakal ngahubungan anjeun pas!
patuh
Layanan Konsumén Online